Toggle menu
Toggle preferences menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Search results

More actions
  • * [[Guide_(Airlock)|Airlocks Guide]] ...
    959 bytes (165 words) - 17:24, 8 March 2026
  • ...[Power Controller]], glass lid on consoles and to open and close unpowered airlocks and doors, as well as in the creation of many advanced machines. ...
    944 bytes (122 words) - 17:39, 8 March 2026
  • ...plots. [[Guide_(Airlock)_Atmosphere_to_Atmosphere|Atmosphere-to-Atmosphere Airlocks]] should be used to travel between these spaces, reinforced with [[Steel Fr ...
    2 KB (270 words) - 14:18, 12 January 2026
  • *<span style="color:#E5BF00;font-weight:bold">[Fixed]</span> airlocks entering an error state when cables are removed; now recoverable when cable ...
    3 KB (351 words) - 20:16, 10 August 2025
  • ...mainly centered around pain points to do with slow process cycling larger airlocks, and a few oddities of the heat exchanger. * Added Powered Vent. New 2x2 vent designed for larger airlocks, it is able to efficiently vacuum out small-medium sized rooms. ...
    8 KB (1,141 words) - 12:42, 24 November 2023
  • Additional consoles are useful when airlocks become large or remote control is desired. Multiple [[Circuitboard (Advance ...essurize" button on a console, but atmospheric mixing may occur. In larger airlocks, ensure there is one Gas Sensor per Large Grid to prevent premature repress ...
    8 KB (1,263 words) - 17:23, 8 March 2026
  • ...ngle frame to avoid leftover atmosphere after depressurization. For larger airlocks place the sensor on the far side from the vents. The script supports [[Blas ...
    4 KB (621 words) - 09:39, 20 February 2026
  • ...itional information regarding the function, construction, and operation of airlocks. ...
    4 KB (555 words) - 17:23, 8 March 2026
  • ...into a pipe network. Its primary purpose is for the creation of multi-grid airlocks. It can efficiently pull a vacuum on a small to medium sized room.</q><br> ...
    4 KB (637 words) - 22:53, 11 February 2026
  • Additional control [[Console]]s are useful when airlocks become large or remote control is desired. A Circuitboard (Airlock) can sup ...
    5 KB (634 words) - 17:22, 8 March 2026
  • Additional control [[Console]]s are useful when airlocks become large or remote control is desired. A Circuitboard (Advanced Airlock ...
    5 KB (751 words) - 17:22, 8 March 2026
  • * "Community Walkthrough: Airlocks" ...
    10 KB (1,260 words) - 02:03, 29 March 2026
  • In larger airlocks, ensure there is one Gas Sensor per Large Grid to prevent the premature ope ...
    7 KB (1,106 words) - 17:23, 8 March 2026
  • ...worlds like Venus whose atmosphere is well above 101kPa. Manually-operated airlocks can not equalise the pressure within the airlock during the exit cycle to t ...
    8 KB (1,161 words) - 17:19, 8 March 2026
  • ...ough it when open, allowing for the traversal of multiple environments via airlocks. ...
    11 KB (1,552 words) - 21:03, 10 August 2025
  • | Airlocks Tutorial ...
    19 KB (2,434 words) - 12:19, 28 February 2026
  • ...to the existing storage but provide more visual variety for your bases and airlocks. A great way to store and organize your new HARM suit. ...
    23 KB (3,610 words) - 10:51, 10 December 2025
  • * Fixed airlocks leaking atmosphere when internal doors are open. 1x1 rooms should no longer * Fixed airlocks not cycling properly on dedicated servers. ...
    118 KB (19,124 words) - 17:39, 8 March 2026
  • *First pass on dock for motherships - they work as airlocks currently except that if an airlock is on a mothership and gets close to a *Fixed airlocks leaking atmosphere when internal doors are open. 1x1 rooms should no longer ...
    151 KB (22,882 words) - 13:53, 27 December 2023
  • ...during storms or even a full airlock if desired. See the [[Guide (Airlock)|Airlocks]] ...
    56 KB (9,814 words) - 17:40, 8 March 2026