<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://stationeers-wiki.com/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=2A00%3A23C5%3ABA02%3A7800%3AE5C0%3A8E1D%3A234E%3A6231</id>
	<title>Stationeers Community Wiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://stationeers-wiki.com/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=2A00%3A23C5%3ABA02%3A7800%3AE5C0%3A8E1D%3A234E%3A6231"/>
	<link rel="alternate" type="text/html" href="https://stationeers-wiki.com/Special:Contributions/2A00:23C5:BA02:7800:E5C0:8E1D:234E:6231"/>
	<updated>2026-04-04T19:24:05Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.43.8</generator>
	<entry>
		<id>https://stationeers-wiki.com/index.php?title=Active_Vent&amp;diff=9058</id>
		<title>Active Vent</title>
		<link rel="alternate" type="text/html" href="https://stationeers-wiki.com/index.php?title=Active_Vent&amp;diff=9058"/>
		<updated>2020-01-05T17:41:42Z</updated>

		<summary type="html">&lt;p&gt;2A00:23C5:BA02:7800:E5C0:8E1D:234E:6231: better gramma&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&amp;lt;languages /&amp;gt;&lt;br /&gt;
&amp;lt;translate&amp;gt;&lt;br /&gt;
&amp;lt;!--T:1--&amp;gt;&lt;br /&gt;
[[Category:Atmospherics]]&lt;br /&gt;
{{Itembox&lt;br /&gt;
 | name        = Active Vent&lt;br /&gt;
 | image       = [[File:ItemActiveVent.png]]&lt;br /&gt;
 | createdwith = [[Hydraulic Pipe Bender]], [[Fabricator]]&lt;br /&gt;
 | cost        = 5g [[Iron]], 1g [[Gold]], 5g [[Copper]]&lt;br /&gt;
 | stacks      = 5&lt;br /&gt;
}}&lt;br /&gt;
{{Structurebox&lt;br /&gt;
 | name             = Active Vent&lt;br /&gt;
 | power_usage      = 100W&lt;br /&gt;
 | placed_with_item = [[Active Vent (Item)]]&lt;br /&gt;
 | placed_on_grid   = Small Grid&lt;br /&gt;
 | decon_with_tool1 = [[Hand Drill]]&lt;br /&gt;
 | item_rec1        = [[Active Vent (Item)]]&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Description == &amp;lt;!--T:2--&amp;gt;&lt;br /&gt;
Used to move gasses from pipes, by using its inward or outward switches. It needs to be powered to function.&lt;br /&gt;
&lt;br /&gt;
Active vents have a build-in pressure sensor and will use it to try to set the external pressure to the value of the &amp;quot;PressureExternal&amp;quot; parameter.&lt;br /&gt;
&lt;br /&gt;
This parameter is set to its default values everytime the mode switch is used. Default values are 101kPa for Outward and 0kPa for Inward.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Note&#039;&#039;&#039;: The insert slot currently takes any item and seems to have no effect.&lt;br /&gt;
&lt;br /&gt;
{{Data Network Header}}&lt;br /&gt;
&lt;br /&gt;
=== Mode Values ===&lt;br /&gt;
These lists the values and meanings for the &amp;quot;Mode&amp;quot; property of the Active Vent.&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Value !! Meaning&lt;br /&gt;
|-&lt;br /&gt;
| 0 || &amp;quot;Outward&amp;quot; mode (Pumping gas from the connected pipe network to the outside.)&lt;br /&gt;
|-&lt;br /&gt;
| 1 || &amp;quot;Inward&amp;quot; mode (Pumping gas from the outside to the connected pipe network.)&lt;br /&gt;
|-&lt;br /&gt;
| 2 || (Unknown)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{{Data Parameters}}&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Parameter Name !! Data Type !! Description&lt;br /&gt;
|-&lt;br /&gt;
| Open || Boolean || Does not function.&lt;br /&gt;
|-&lt;br /&gt;
| Mode || Integer || Sets the Active Vent mode to the passed setting. (See [[#Mode_Values|Mode Values]])&lt;br /&gt;
|-&lt;br /&gt;
| PressureExternal || Float || Sets the desired external pressure (Will be overwritten by a mode switch. NOTE: Setting this on a vent that is running in &amp;quot;Inward&amp;quot; mode seems to close it, preventing flow of gas)&lt;br /&gt;
|-&lt;br /&gt;
| PressureInternal || Float || Does not function.&lt;br /&gt;
|-&lt;br /&gt;
| Lock || Boolean || Locks the Active Vent, when set to 1. Unlocks it, when set to 0.&lt;br /&gt;
|-&lt;br /&gt;
| Setting || Float || Does not function.&lt;br /&gt;
|-&lt;br /&gt;
| On || Boolean || Turns the Active Vent on, when set to 1. Turns it off, when set to 0.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{{Data Outputs}}&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Output Name !! Data Type !! Description&lt;br /&gt;
|-&lt;br /&gt;
| Power || Boolean || Returns whether the Active Vent is receiving power and is turned on. (0 for no, 1 for yes)&lt;br /&gt;
|-&lt;br /&gt;
| Open || Boolean || Returns whether the Active Vent is open. (0 for no, 1 for yes) (Untested)&lt;br /&gt;
|-&lt;br /&gt;
| Mode || Integer || Returns the setting of the current mode of the Active Vent. (See [[#Mode_Values|Mode Values]])&lt;br /&gt;
|-&lt;br /&gt;
| Error || Boolean || Returns whether the Active Vent is currently flashing an error. (0 for no, 1 for yes)&lt;br /&gt;
|-&lt;br /&gt;
| PressureExternal || Float || Returns the desired external pressure of the Active Vent.&lt;br /&gt;
|-&lt;br /&gt;
| PressureInternal || Float || Returns the desired internal pressure of the Active vent. (Untested)&lt;br /&gt;
|-&lt;br /&gt;
| Lock || Boolean || Returns whether the Active Vent is locked. (0 for no, 1 for yes)&lt;br /&gt;
|-&lt;br /&gt;
| Setting || Float || Returns a range from 0.0 to 100.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent.&lt;br /&gt;
|-&lt;br /&gt;
| Maximum || Integer || Returns 100. (Assumption) Returns the maximum throughput percentage of the Active Vent.&lt;br /&gt;
|-&lt;br /&gt;
| Ratio || Float || Returns a range from 0.0 to 1.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent.&lt;br /&gt;
|-&lt;br /&gt;
| On || Boolean || Returns whether the Active Vent is set to on. (0 for no, 1 for yes)&lt;br /&gt;
|-&lt;br /&gt;
| RequiredPower || Integer || Returns the current amount of power needed for the Active Vent.&lt;br /&gt;
|}&lt;br /&gt;
&amp;lt;/translate&amp;gt;&lt;/div&gt;</summary>
		<author><name>2A00:23C5:BA02:7800:E5C0:8E1D:234E:6231</name></author>
	</entry>
	<entry>
		<id>https://stationeers-wiki.com/index.php?title=Active_Vent&amp;diff=9057</id>
		<title>Active Vent</title>
		<link rel="alternate" type="text/html" href="https://stationeers-wiki.com/index.php?title=Active_Vent&amp;diff=9057"/>
		<updated>2020-01-05T17:40:44Z</updated>

		<summary type="html">&lt;p&gt;2A00:23C5:BA02:7800:E5C0:8E1D:234E:6231: Added note about Inward mode + ExternalPressure&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&amp;lt;languages /&amp;gt;&lt;br /&gt;
&amp;lt;translate&amp;gt;&lt;br /&gt;
&amp;lt;!--T:1--&amp;gt;&lt;br /&gt;
[[Category:Atmospherics]]&lt;br /&gt;
{{Itembox&lt;br /&gt;
 | name        = Active Vent&lt;br /&gt;
 | image       = [[File:ItemActiveVent.png]]&lt;br /&gt;
 | createdwith = [[Hydraulic Pipe Bender]], [[Fabricator]]&lt;br /&gt;
 | cost        = 5g [[Iron]], 1g [[Gold]], 5g [[Copper]]&lt;br /&gt;
 | stacks      = 5&lt;br /&gt;
}}&lt;br /&gt;
{{Structurebox&lt;br /&gt;
 | name             = Active Vent&lt;br /&gt;
 | power_usage      = 100W&lt;br /&gt;
 | placed_with_item = [[Active Vent (Item)]]&lt;br /&gt;
 | placed_on_grid   = Small Grid&lt;br /&gt;
 | decon_with_tool1 = [[Hand Drill]]&lt;br /&gt;
 | item_rec1        = [[Active Vent (Item)]]&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Description == &amp;lt;!--T:2--&amp;gt;&lt;br /&gt;
Used to move gasses from pipes, by using its inward or outward switches. It needs to be powered to function.&lt;br /&gt;
&lt;br /&gt;
Active vents have a build-in pressure sensor and will use it to try to set the external pressure to the value of the &amp;quot;PressureExternal&amp;quot; parameter.&lt;br /&gt;
&lt;br /&gt;
This parameter is set to its default values everytime the mode switch is used. Default values are 101kPa for Outward and 0kPa for Inward.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Note&#039;&#039;&#039;: The insert slot currently takes any item and seems to have no effect.&lt;br /&gt;
&lt;br /&gt;
{{Data Network Header}}&lt;br /&gt;
&lt;br /&gt;
=== Mode Values ===&lt;br /&gt;
These lists the values and meanings for the &amp;quot;Mode&amp;quot; property of the Active Vent.&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Value !! Meaning&lt;br /&gt;
|-&lt;br /&gt;
| 0 || &amp;quot;Outward&amp;quot; mode (Pumping gas from the connected pipe network to the outside.)&lt;br /&gt;
|-&lt;br /&gt;
| 1 || &amp;quot;Inward&amp;quot; mode (Pumping gas from the outside to the connected pipe network.)&lt;br /&gt;
|-&lt;br /&gt;
| 2 || (Unknown)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{{Data Parameters}}&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Parameter Name !! Data Type !! Description&lt;br /&gt;
|-&lt;br /&gt;
| Open || Boolean || Does not function.&lt;br /&gt;
|-&lt;br /&gt;
| Mode || Integer || Sets the Active Vent mode to the passed setting. (See [[#Mode_Values|Mode Values]])&lt;br /&gt;
|-&lt;br /&gt;
| PressureExternal || Float || Sets the desired external pressure (Will be overwritten by a mode switch. NOTE: Setting this on a vent that is running in &amp;quot;Inward&amp;quot; mode seems to close the vent while it&#039;s running, causing it to move no gas)&lt;br /&gt;
|-&lt;br /&gt;
| PressureInternal || Float || Does not function.&lt;br /&gt;
|-&lt;br /&gt;
| Lock || Boolean || Locks the Active Vent, when set to 1. Unlocks it, when set to 0.&lt;br /&gt;
|-&lt;br /&gt;
| Setting || Float || Does not function.&lt;br /&gt;
|-&lt;br /&gt;
| On || Boolean || Turns the Active Vent on, when set to 1. Turns it off, when set to 0.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{{Data Outputs}}&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Output Name !! Data Type !! Description&lt;br /&gt;
|-&lt;br /&gt;
| Power || Boolean || Returns whether the Active Vent is receiving power and is turned on. (0 for no, 1 for yes)&lt;br /&gt;
|-&lt;br /&gt;
| Open || Boolean || Returns whether the Active Vent is open. (0 for no, 1 for yes) (Untested)&lt;br /&gt;
|-&lt;br /&gt;
| Mode || Integer || Returns the setting of the current mode of the Active Vent. (See [[#Mode_Values|Mode Values]])&lt;br /&gt;
|-&lt;br /&gt;
| Error || Boolean || Returns whether the Active Vent is currently flashing an error. (0 for no, 1 for yes)&lt;br /&gt;
|-&lt;br /&gt;
| PressureExternal || Float || Returns the desired external pressure of the Active Vent.&lt;br /&gt;
|-&lt;br /&gt;
| PressureInternal || Float || Returns the desired internal pressure of the Active vent. (Untested)&lt;br /&gt;
|-&lt;br /&gt;
| Lock || Boolean || Returns whether the Active Vent is locked. (0 for no, 1 for yes)&lt;br /&gt;
|-&lt;br /&gt;
| Setting || Float || Returns a range from 0.0 to 100.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent.&lt;br /&gt;
|-&lt;br /&gt;
| Maximum || Integer || Returns 100. (Assumption) Returns the maximum throughput percentage of the Active Vent.&lt;br /&gt;
|-&lt;br /&gt;
| Ratio || Float || Returns a range from 0.0 to 1.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent.&lt;br /&gt;
|-&lt;br /&gt;
| On || Boolean || Returns whether the Active Vent is set to on. (0 for no, 1 for yes)&lt;br /&gt;
|-&lt;br /&gt;
| RequiredPower || Integer || Returns the current amount of power needed for the Active Vent.&lt;br /&gt;
|}&lt;br /&gt;
&amp;lt;/translate&amp;gt;&lt;/div&gt;</summary>
		<author><name>2A00:23C5:BA02:7800:E5C0:8E1D:234E:6231</name></author>
	</entry>
</feed>