<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://stationeers-wiki.com/index.php?action=history&amp;feed=atom&amp;title=Liquid_Digital_Valve</id>
	<title>Liquid Digital Valve - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://stationeers-wiki.com/index.php?action=history&amp;feed=atom&amp;title=Liquid_Digital_Valve"/>
	<link rel="alternate" type="text/html" href="https://stationeers-wiki.com/index.php?title=Liquid_Digital_Valve&amp;action=history"/>
	<updated>2026-04-05T05:12:22Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.8</generator>
	<entry>
		<id>https://stationeers-wiki.com/index.php?title=Liquid_Digital_Valve&amp;diff=21127&amp;oldid=prev</id>
		<title>Kahsikmahn: Added Liquid Digital Valve Page</title>
		<link rel="alternate" type="text/html" href="https://stationeers-wiki.com/index.php?title=Liquid_Digital_Valve&amp;diff=21127&amp;oldid=prev"/>
		<updated>2024-06-04T02:12:44Z</updated>

		<summary type="html">&lt;p&gt;Added Liquid Digital Valve Page&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;[[Category:Atmospherics]]&lt;br /&gt;
{{Itembox&lt;br /&gt;
 | name        = Liquid Digital Valve&lt;br /&gt;
 | image       = [[File:ItemLiquidDigitalValve.png]]&lt;br /&gt;
 | stacks      = 1&lt;br /&gt;
 | createdwith = [[Hydraulic Pipe Bender]], [[Fabricator]]&lt;br /&gt;
 | cost        = 2g [[Copper Ingot|Copper]], 5g [[Steel Ingot|Steel]], 3g [[Invar Ingot|Invar]]&lt;br /&gt;
}}&lt;br /&gt;
=Liquid Digital Valve=&lt;br /&gt;
==Description==&lt;br /&gt;
A valve which can be operated by logic network. Switching its &amp;quot;On&amp;quot; variable to 1 causes the valve to be fully open, switching to 0 closes the valve to completely close. &lt;br /&gt;
Power usage: 0 Watts when off. 5 Watts when on. &lt;br /&gt;
&lt;br /&gt;
{{Data Network Header}}&lt;br /&gt;
&lt;br /&gt;
{{Data Parameters}}&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Parameter Name !! Data Type !! Description&lt;br /&gt;
|-&lt;br /&gt;
| Lock || Boolean || Locks the Liquid Digital Valve, when set to 1. Unlocks it, when set to 0.&lt;br /&gt;
|-&lt;br /&gt;
| Setting || Float || Does not function.&lt;br /&gt;
|-&lt;br /&gt;
| On || Boolean || Turns the Liquid Digital Valve on, when set to 1. Turns it off, when set to 0.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{{Data Outputs}}&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Output Name !! Data Type !! Description&lt;br /&gt;
|-&lt;br /&gt;
| Maximum || Integer || Returns 100. (Assumption) Returns the maximum throughput percentage of the Liquid Digital Valve.&lt;br /&gt;
|-&lt;br /&gt;
| Lock || Boolean || Returns whether the Liquid Digital Valve is locked. (0 for no, 1 for yes)&lt;br /&gt;
|-&lt;br /&gt;
| Error || Boolean || Returns whether the Liquid Digital Valve is currently flashing an error. (0 for no, 1 for yes)&lt;br /&gt;
|-&lt;br /&gt;
| Setting || Float || Returns a range from 0.0 to 100.0. Does not function. (Assumption) Returns the percentage of opening of the Liquid Digital Valve.&lt;br /&gt;
|-&lt;br /&gt;
| RequiredPower || Integer || Returns the current amount of power needed for the Liquid Digital Valve.&lt;br /&gt;
|-&lt;br /&gt;
| Ratio || Float || Returns a range from 0.0 to 1.0. Does not function. (Assumption) Returns the differential in pressure between the sides of the Liquid Digital Valve.&lt;br /&gt;
|-&lt;br /&gt;
| Prefab Hash || Integer || (Assumption) Returns (-517628750) a unique type identifier for the Liquid Digital Valve.&lt;br /&gt;
|-&lt;br /&gt;
| Power || Boolean || Returns whether the Liquid Digital Valve is receiving power and is turned on. (0 for no, 1 for yes)&lt;br /&gt;
|-&lt;br /&gt;
| On || Boolean || Returns whether the Liquid Digital Valve is set to on. (0 for no, 1 for yes)&lt;br /&gt;