Toggle menu
Toggle preferences menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Combustor: Difference between revisions

From Stationeers Community Wiki
RA2lover (talk | contribs)
Logic: Correct Activate behavior. FIXME: update to new logic template later
RA2lover (talk | contribs)
Update article to fit 0.2.6400.27672 mechanics (increased surface area to 2x2x3 size, added liquid pipe input, removed pressure gradient impact, added setting wheel, increased power consumption to 1200W)
 
(10 intermediate revisions by 3 users not shown)
Line 1: Line 1:
[[Category:Atmospherics]]
[[Category:Atmospherics]]
<languages/>
<blockquote>
<translate>
The Combustor performs controlled combustion of a mixture drawn from a gas input and a liquid input. A control wheel sets the ratio taken from each, much like the [[Gas Mixer]], and the combined mixture is combusted just before being passed to the output.
{{Structurebox
 
  | name            = H2 Combustor
What the Combustor produces depends entirely on  what is fed into it. See the [[Gases and Liquids|Gases]] page to find what each combination combusts into.
 
-[[Stationpedia]]</blockquote>{{Structurebox
  | name            = Combustor
  | image            = [[File:H2 Combustor.jpg]]
  | image            = [[File:H2 Combustor.jpg]]
  | power_usage      = 10W
  | power_usage      = 1200W
  | placed_with_item = [[Kit (Atmospherics)]]
  | placed_with_item = [[Kit (Atmospherics)]]
  | placed_on_grid  = Small Grid
  | placed_on_grid  = Small Grid
| requires_frames  = Yes
  | decon_with_tool1 = [[Drill]]
  | decon_with_tool1 = [[Drill]]
  | item_rec1        = [[Kit (Atmospherics)]]
  | item_rec1        = [[Kit (Atmospherics)]]
}}
|paintable=Yes|constructable_in_rockets=No|volume=1000 L|prefab_name=StructureCombustor|prefab_hash=-1037204948|convection=0.72315187|radiation=0.72315187|solar_heating=0.72315187|stage_image1=[[File:H2Combustor BuildState0.png]]|stage_image2=[[File:H2Combustor BuildState1.png]]|const_with_item2=2x [[Kit (Pipe)]]|decon_with_tool2=[[Wrench]]|item_rec2=2x [[Kit (Pipe)]]|stage_image3=[[File:H2Combustor BuildState2.png]]|const_with_tool3=[[Screwdriver]]|const_with_item3=2x [[Cable Coil]]|const_with_item1=[[Kit (Atmospherics)]]}}
<!--T:1-->
=Description=
=Description=
Burns a fuel mixture of volatiles and oxygen to produce high-temperature [[Water|Steam]].  The H2 Combustor should be fed a 2:1 ratio of volatiles to oxygen.  It will output mix of gases at 2500 C, made up of approximately 46.67% [[Carbon Dioxide]], 30% [[Water|Steam]], and 23.33% [[Pollutant|Pollutants]], plus trace amounts of unburnt volatiles and oxygen.
Burns a [[fuel]] mixture to produce high-temperature byproducts.  


To generate electricity with fuel instead, see the [[Kit (Gas Fuel Generator)|Gas Fuel Generator]]. Alternatively, the heat generated by the H2 Combustor may be used with a [[Kit (Stirling Engine)|Stirling Engine]] to generate power at a much lower efficiency.
To generate electricity with fuel instead, see the [[Kit (Gas Fuel Generator)|Gas Fuel Generator]]. Alternatively, the heat generated by the H2 Combustor may be used with a [[Kit (Stirling Engine)|Stirling Engine]] to generate [[power]] at a lower efficiency.


However, while lower efficiency than a Gas Fuel Generator, in terms of energy output per mole of fuel input, a [[Stirling Engine]] is a practical and effective first step for cooling the output due to the fact that it generates power from cooling, rather than consuming power to cool the output (such as with an [[Air Conditioner]]). Depending on the exact setup, and how efficiently the Stirling Engine can be cooled (best on cold non-vacuum planets like Europa and Mars), it's possible for the Stirling Engine to offset the power cost of H2 Combustor, Filtration, and the entire rest of the cooling system, resulting in a zero-loss or even net-positive system. Alternatively, the outputs may be air-cooled using radiators on cooler planets or in a vacuum.
However, while lower efficiency than a [[Gas Fuel Generator]], in terms of [[energy]] output per mole of fuel input, a [[Stirling Engine]] is a practical and effective first step for cooling the output due to the fact that it generates power from cooling, rather than consuming power to cool the output (such as with an [[Air Conditioner]]). Depending on the exact setup, and how efficiently the Stirling Engine can be cooled (best on cold non-vacuum [[planets]] like [[Europa]] and [[Mars]]), it's possible for the Stirling Engine to offset the power cost of the Combustor, [[Filtration]], and the entire rest of the cooling system, resulting in a zero-loss or even net-positive system. Alternatively, the outputs may be air-cooled using radiators on cooler planets or in a vacuum.


200 Moles of Volatiles and 100 Moles of Oxygen will produce 135 Moles of Water + Waste products.
=Characteristics=


<!--T:2-->
* Total pumping capacity per tick from inputs is 101.325 kPa * 10 L at one network's temperature, regardless of pressure gradient.
=Characteristics=
** Only one of the two input pipes needs to be connected.  
* Consumes fuel from the input, requiring a 2:1 mix of volatiles to oxygen.  Imprecise ratios will result in lower production rate, and the unburnt excess in the output.
** Temperature chosen for pumping capacity calculation prioritizes liquid input temperature, then gas input temperature, then internal temperature, in that order.
* Produces approximately 46% more moles output than the fuel input consumed.
** Pumping capacity is distributed across both inputs based on the ''Setting'' logic parameter, which can also be adjusted through the control wheel.
* Rate of fuel consumption from the input, and thus rate of production, is based on the pressure of the input. The unit will consume 3.42 L of fuel from the input each tick.
*** If one of the inputs lacks sufficient contents to meet the demanded pumping capacity, additional contents are pulled from the other input in order to maintain the total pumping capacity at the cost of ratiometric balance, unlike the [[Gas Mixer]] where pumping is stopped altogether.
* Has an internal volume of 100L, where the product of the combustion is stored before being pushed to the output pipe.
* The device consumes 1200 W while powered, even when idle.
* The unit, and gas inside it, will interact with the surrounding environment, as well as radiating heat in a vacuum (and thus cooling the gas inside it).  In an air-filled room, this will significantly heat the surroundings.
* Has an internal volume of 1000 L, where the product of the combustion is stored before being equalized to the output [[pipe]].
* The initial temperature of the products is 2500 C.
** Equalization only happens while the combustor is powered on and only happens unidirectionally to the output pipe.
* The water in the output is initially produced as a liquid before rapidly evaporating due to the temperature.  This results in noticeable innate cooling of the output, up to ~100 C.  Further losses from radiation or convection cooling of the surroundings also assist with this.
** If the unit is switched off, whatever gas remains in the unit will continue cooling through radiation or convection without equalizing to the output pipe.
* Each tick that the unit is ''turned on'', it will first equalize its internal volume with the output pipe network, before pulling in and combusting more fuel to add to the internal volume.
 
** This only occurs when the unit is turned on, so if the unit is switched off, whatever gas remains in the unit will continue cooling through radiation or convection without equalizing to the output pipe.
* Each [[tick]] that the unit is ''turned on'', it will first equalize its internal volume with the output [[Pipe Network|pipe network]], before pulling in and combusting more fuel to add to the internal volume.
** Since the equalization occurs before more fuel is pulled in, after the first tick the unit is on, it will have gases stored inside it but won't have pushed any to the output pipe yet.
** Since the equalization occurs before more fuel is pulled in, after the first tick the unit is on, it will have gases stored inside it but won't have pushed any to the output pipe yet.
** Has a ''Mode'' variable that can be set to 0 to allow the unit to be kept on, and continue to push gases to the output, without pulling more fuel in.
** Has a ''Mode'' variable that can be set to 0 to allow the unit to be kept on, and continue to equalize gases with the output, without pulling more fuel in.
* Consumes only 10 W of power even when running.
* The unit, and gas inside it, will interact with the surrounding environment, as well as radiating heat in a vacuum (and thus cooling the gas inside it).  In an air-filled [[room]], this will significantly heat the surroundings.


=== Logic ===
=== Logic ===
These are all the logic parameters of the device.
These are all the [[logic]] parameters of the device.
<!--T:4-->
{| class="wikitable"
{| class="wikitable"
|-
|-
Line 45: Line 47:
| On || Boolean || Read/Write || The current state of the device, 0 for off, 1 for on.
| On || Boolean || Read/Write || The current state of the device, 0 for off, 1 for on.
|-
|-
| Mode || Boolean || Read/Write || Whether the unit pulls in and/or combusts fuel input, if the unit is also turned on.  1 (default) = ''Active'' mode, 0 = ''Idle'' mode.
| Mode || Boolean || Read/Write || Whether the unit pulls in more fuel to combust, if the unit is also turned on.  1 (default) for pulling more fuel in, 0 to disable input.
|-
|-
| Activate || Boolean || Read/Write || Whether the unit ignites fuel (1) or pulls in more fuel (0) when in ''Active'' mode. Toggles states each tick in Active mode unless overridden by logic.
| Activate || Boolean || Read/Write || Whether the unit pulled fuel in last tick. May not sync with ''Mode'' if no fuel could be pulled from the input.
|-
|-
| RequiredPower|| Float || Read-only || Idle and active operating power quantity.  10W.
| RequiredPower|| Float || Read-only || Idle and active operating power quantity.  1200 W.
|-
|-
| Error || Boolean || Read-only || 1 if the device is in error state, otherwise 0.
| Error || Boolean || Read-only || 1 if the device is in error state, otherwise 0.
Line 55: Line 57:
| Power || Float  || Read-only || Can be read to return if the device is correctly powered or not, set via power system, return 1 if powered and 0 if not.
| Power || Float  || Read-only || Can be read to return if the device is correctly powered or not, set via power system, return 1 if powered and 0 if not.
|-
|-
| Setting || Integer || Read/Write || No effect.
| Setting || Float || Read/Write || Adjusts the molar intake ratio between inputs. Range: 0..100.
0: 0% liquid input, 100% gas input.
100: 100% liquid input, 0% gas input.
|-
|-
| Lock || Boolean || Read/Write || 1 if a device is locked, otherwise 0, can be set in most devices and prevents the user from writing values.
| Lock || Boolean || Read/Write || 1 if a device is locked, otherwise 0, can be set in most devices and prevents the user from writing values.
|-
|-
| PrefabHash || Integer || Read-only || The hash of the structure.
| PrefabHash || Integer || Read-only || The [[hash]] of the structure.
|-
|-
| Maximum || Float || Read-only || Maximum setting of the device.
| Maximum || Float || Read-only || Maximum setting of the device.
|-
|-
| Ratio || Float || Read-only || Context specific value depending on the device, 0 to based ratio.
| Ratio || Float || Read-only || Percentage conversion of the Setting parameter.
|}
|}


=See Also=
=See Also=
* [[Kit (Atmospherics)]]
* [[Kit (Atmospherics)]]
</translate>

Latest revision as of 06:12, 30 June 2026

The Combustor performs controlled combustion of a mixture drawn from a gas input and a liquid input. A control wheel sets the ratio taken from each, much like the Gas Mixer, and the combined mixture is combusted just before being passed to the output.

What the Combustor produces depends entirely on what is fed into it. See the Gases page to find what each combination combusts into.

-Stationpedia

Combustor
Paintable Yes
Constructable in Rockets No
Operation
Power Usage 1200W
Volume 1000 L
Thermal Convection 0.72315187
Thermal Radiation 0.72315187
Solar Heating 0.72315187
Prefab Hash -1037204948
Prefab Name StructureCombustor
Construction
Placed with Kit (Atmospherics)
Placed on Small Grid
Paintable Yes
Requires Frame Yes
Stage 1
Next Stage Construction
Constructed with item Kit (Atmospherics)
Deconstruction
Deconstructed with Drill
Item received Kit (Atmospherics)
Stage 2
Next Stage Construction
Constructed with item 2x Kit (Pipe)
Deconstruction
Deconstructed with Wrench
Item received 2x Kit (Pipe)
Stage 3
Next Stage Construction
Constructed with tool Screwdriver
Constructed with item 2x Cable Coil

Description

Burns a fuel mixture to produce high-temperature byproducts.

To generate electricity with fuel instead, see the Gas Fuel Generator. Alternatively, the heat generated by the H2 Combustor may be used with a Stirling Engine to generate power at a lower efficiency.

However, while lower efficiency than a Gas Fuel Generator, in terms of energy output per mole of fuel input, a Stirling Engine is a practical and effective first step for cooling the output due to the fact that it generates power from cooling, rather than consuming power to cool the output (such as with an Air Conditioner). Depending on the exact setup, and how efficiently the Stirling Engine can be cooled (best on cold non-vacuum planets like Europa and Mars), it's possible for the Stirling Engine to offset the power cost of the Combustor, Filtration, and the entire rest of the cooling system, resulting in a zero-loss or even net-positive system. Alternatively, the outputs may be air-cooled using radiators on cooler planets or in a vacuum.

Characteristics

  • Total pumping capacity per tick from inputs is 101.325 kPa * 10 L at one network's temperature, regardless of pressure gradient.
    • Only one of the two input pipes needs to be connected.
    • Temperature chosen for pumping capacity calculation prioritizes liquid input temperature, then gas input temperature, then internal temperature, in that order.
    • Pumping capacity is distributed across both inputs based on the Setting logic parameter, which can also be adjusted through the control wheel.
      • If one of the inputs lacks sufficient contents to meet the demanded pumping capacity, additional contents are pulled from the other input in order to maintain the total pumping capacity at the cost of ratiometric balance, unlike the Gas Mixer where pumping is stopped altogether.
  • The device consumes 1200 W while powered, even when idle.
  • Has an internal volume of 1000 L, where the product of the combustion is stored before being equalized to the output pipe.
    • Equalization only happens while the combustor is powered on and only happens unidirectionally to the output pipe.
    • If the unit is switched off, whatever gas remains in the unit will continue cooling through radiation or convection without equalizing to the output pipe.
  • Each tick that the unit is turned on, it will first equalize its internal volume with the output pipe network, before pulling in and combusting more fuel to add to the internal volume.
    • Since the equalization occurs before more fuel is pulled in, after the first tick the unit is on, it will have gases stored inside it but won't have pushed any to the output pipe yet.
    • Has a Mode variable that can be set to 0 to allow the unit to be kept on, and continue to equalize gases with the output, without pulling more fuel in.
  • The unit, and gas inside it, will interact with the surrounding environment, as well as radiating heat in a vacuum (and thus cooling the gas inside it). In an air-filled room, this will significantly heat the surroundings.

Logic

These are all the logic parameters of the device.

Parameter Type Access Description
On Boolean Read/Write The current state of the device, 0 for off, 1 for on.
Mode Boolean Read/Write Whether the unit pulls in more fuel to combust, if the unit is also turned on. 1 (default) for pulling more fuel in, 0 to disable input.
Activate Boolean Read/Write Whether the unit pulled fuel in last tick. May not sync with Mode if no fuel could be pulled from the input.
RequiredPower Float Read-only Idle and active operating power quantity. 1200 W.
Error Boolean Read-only 1 if the device is in error state, otherwise 0.
Power Float Read-only Can be read to return if the device is correctly powered or not, set via power system, return 1 if powered and 0 if not.
Setting Float Read/Write Adjusts the molar intake ratio between inputs. Range: 0..100.

0: 0% liquid input, 100% gas input. 100: 100% liquid input, 0% gas input.

Lock Boolean Read/Write 1 if a device is locked, otherwise 0, can be set in most devices and prevents the user from writing values.
PrefabHash Integer Read-only The hash of the structure.
Maximum Float Read-only Maximum setting of the device.
Ratio Float Read-only Percentage conversion of the Setting parameter.

See Also

Contents