Toggle menu
Toggle preferences menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Electrolyzer: Difference between revisions

From Stationeers Community Wiki
Katree (talk | contribs)
mNo edit summary
Kaedys (talk | contribs)
Updated description to match current in-game description. Updated notes for more clarity around auto-ignition
 
(4 intermediate revisions by one other user not shown)
Line 5: Line 5:
  | placed_with_item = [[Kit (Atmospherics)]]
  | placed_with_item = [[Kit (Atmospherics)]]
  | placed_on_grid  = Small Grid
  | placed_on_grid  = Small Grid
| requires_frames  = Yes
  | decon_with_tool1 = [[Hand Drill]]
  | decon_with_tool1 = [[Hand Drill]]
  | item_rec1        = [[Kit (Atmospherics)]]
  | item_rec1        = [[Kit (Atmospherics)]]
Line 11: Line 12:
=Description=
=Description=


Storing water got you down? At the expense of power, you can turn that excess water into a bunch of heat and a somewhat risky mix of Oxygen and Volatiles using the new Electrolysis Machine. Available on the existing Atmospherics kit with Air Conditioners and Filtration machines.
The ''Norsec-designed'' Electrolyzer splits [[Water]] into [[Hydrogen]] and [[Oxygen]].  Employing unknown proprietary technology, the devices uses water's latent heat as energy to drive the electrolysis<!-- corrected from in-game, which uses "electrosis" here, as of v0.2.6227.27061 on 15 June 2026 --> process.  If there is a downside to this near-miraculous fission, it's that the devices is limited by the quantity of power available, which is used to maintain the temperature output. In other words, the machine works best with hot gas.


=Usage=
=Usage=
Line 19: Line 20:


=Notes=
=Notes=
* Higher water temperatures result in slightly higher efficiency leading to marginally higher production rates. https://en.wikipedia.org/wiki/High-temperature_electrolysis
* The conversion rate is 3 mol [[Water|H2O]] produces 1 mol [[Oxygen|O2]] and 2 mol [[Hydrogen|H2]].
* The Electrolyzer always outputs at 20°C.
* H2 and O2 are produced mixed together in a single gas pipe, creating a dangerous fuel mixture that can be directly used in a furnace.
* H2 and O2 are produced mixed together in a single gas pipe, creating a dangerous fuel mixture that can be directly used in a furnace.
* Assuming in vacuum conditions, the Electrolyzer always outputs [[Oxyhydrogen]] (ie fuel) at 20 Celcius. https://en.wikipedia.org/wiki/High-temperature_electrolysis
** If the temperature inside the electrolyzer output network rises above 300&#176;C, autoignition of the output fuel mixture will occur, creating significant additional heat and converting virtually all of the O2 and H2 in the output network into Steam, and causing further outputs from the electrolyzer to immediately autocombust as well, due to the resulting high temperature of the output network. Using insulated pipes is highly recommended, especially on hot worlds.
* The conversion rate is 1 mol [[Water|H2O]] produces 1 mol [[Oxygen|O2]] and 2 mols [[Volatiles|H2]].
* If the temperature inside the Electrolyzer reaches 300C, autoignition occurs, creating heat, and converting virtually all O2 and H2 inside the machine into CO2 and X. Keep this in mind on high-temperature worlds.
* If autoignition occurs, it doesn't propagate to the gas pipe connected to the Electrolyzer, so the gas already removed is safe, provided it is insulated from further temperature increases.
* The Electrolyzer's internal volume is generally separated from the pipe network, and it can release its content only if the machine is turned on.


{{Data Network Header}}
{{Data Network Header}}

Latest revision as of 00:03, 20 June 2026

Electrolyzer
Operation
Power Usage 3600W
Construction
Placed with Kit (Atmospherics)
Placed on Small Grid
Paintable No
Requires Frame Yes
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Atmospherics)


Description

The Norsec-designed Electrolyzer splits Water into Hydrogen and Oxygen. Employing unknown proprietary technology, the devices uses water's latent heat as energy to drive the electrolysis process. If there is a downside to this near-miraculous fission, it's that the devices is limited by the quantity of power available, which is used to maintain the temperature output. In other words, the machine works best with hot gas.

Usage

  1. Select Kit (Atmospherics) for placement, and change the variant to Electrolyzer.
  2. Connect liquid pipe to the Input liquid connection to transfer water into the machine.
  3. Connect gas pipe to the Output gas connection to remove the created H2 and O2.

Notes

  • Higher water temperatures result in slightly higher efficiency leading to marginally higher production rates. https://en.wikipedia.org/wiki/High-temperature_electrolysis
  • The conversion rate is 3 mol H2O produces 1 mol O2 and 2 mol H2.
  • The Electrolyzer always outputs at 20°C.
  • H2 and O2 are produced mixed together in a single gas pipe, creating a dangerous fuel mixture that can be directly used in a furnace.
    • If the temperature inside the electrolyzer output network rises above 300°C, autoignition of the output fuel mixture will occur, creating significant additional heat and converting virtually all of the O2 and H2 in the output network into Steam, and causing further outputs from the electrolyzer to immediately autocombust as well, due to the resulting high temperature of the output network. Using insulated pipes is highly recommended, especially on hot worlds.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Lock Boolean Locks the Electrolyzer , when set to 1. Unlocks it, when set to 0.
On Boolean Turns the Electrolyzer on, when set to 1. Turns it off, when set to 0.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Electrolyzer is turned on and receives power. (0 for no, 1 for yes)
Error Boolean Returns whether the Electrolyzer is flashing an error. (0 for no, 1 for yes)
Lock Boolean Returns whether the Electrolyzer is locked. (0 for no, 1 for yes)
On Boolean Returns whether the Electrolyzer is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power, required by the Electrolyzer, in Watts.