Toilet: Difference between revisions
From Stationeers Community Wiki
More actions
Created stub from decompiled mechanics from Beta 0.2.6333.27304 |
Update to Beta 0.2.6336.27321. Luckily seems like the only thing changed were the minimum requirements being set to 1% sanitation instead of 25% before being set back in-between. |
||
| (2 intermediate revisions by the same user not shown) | |||
| Line 19: | Line 19: | ||
* 50 mols of Water are removed from the input network. <!-- 50 mols of liquids, of which only water is recovered. Because of the input pipe only being allowed to contain water as liquids, this is only water by definition. --> | * 50 mols of Water are removed from the input network. <!-- 50 mols of liquids, of which only water is recovered. Because of the input pipe only being allowed to contain water as liquids, this is only water by definition. --> | ||
* Return the 50 mols back, plus a substantial amount of polluted water proportional to | * Return the 50 mols back as polluted water, plus a substantial amount of polluted water proportional to restored sanitation, into the output. | ||
** For a full sanitation | ** For a full sanitation recovery, a toilet use recovers 5 L of water (not counting the 50 mols used for flushing). | ||
Latest revision as of 23:27, 10 June 2026
Description
| Paintable | Yes |
|---|---|
| Operation | |
| Prefab Hash | 768716816 |
| Prefab Name | StructureToiletModern |
| Construction | |
| Placed with | Kit (Toilet) |
| Placed on | {{{placed_on_grid}}} |
| Paintable | Yes |
In order to function, the following requires need to be met:
- Connected input and output liquid pipe networks.
- Input pipe atmosphere must have at least 50 mols of clean Water as the only liquid present.
- Input pipe atmosphere must have no Methane, Pollutant, Hydrazine, Hydrochloric Acid or Silanol.
- Input pipe atmosphere must be between 0°C and 100°C.
- Surrounding world atmosphere must have at least 30 kPa of pressure.
- Output network must have at least 1 L of volume available for liquids.
In order to be used, the following criteria need to be met:
- The player has lost at least 25% Sanitation.
- The user needs to be in the same world grid as the toilet.
- The player cannot be wearing anything on their Suit slot.
| Properties | |
|---|---|
| Stacks | Yes (5) |
| Paintable | Yes |
| Autoignition | 573 K |
| Flashpoint | 373 K |
| Logic | |
| Item Hash | 1484917493 |
| Item Name | ItemKitToilet |
When used:
- 50 mols of Water are removed from the input network.
- Return the 50 mols back as polluted water, plus a substantial amount of polluted water proportional to restored sanitation, into the output.
- For a full sanitation recovery, a toilet use recovers 5 L of water (not counting the 50 mols used for flushing).